12/2-2 MC Cable 120V 2 Hots 2 Neutrals Ground 250 FT Coil
12/2-2 MC Cable 120V 2 Hots 2 Neutrals Ground 250 FT Coil
Multiple | ID: 115291
Manufacturer Part Number: 3904-42-00

Technical Documents
Specifications
| Description | CABLE MCAL-12/2-2-WG-SOL-120V 250'2-HOT 2-NEUTRAL 1-GROUND-120V*** SOLID *** |
| Voltage Rating | 600V |
| Application | For branch circuit wiring for a variety of power distribution systems from lighting, to devices and receptacles, branch circuit to computers and other electronic equipment where additive harmonics currents from non-linear switching loads may be present |
| Armour | Interlocked Galvanized Steel Strip |
| Bend Radius | 8.79 |
| Catalog Description (MFR) | 12-2/12-2/12-1 BK RD WE/BK WE/RD GN MC Plus®, White Interlocked Galvanized Steel Armor with phase ID, 250' Coil, Type MC - Neutral Per Phase |
| Color | Black, Red, White w/Black Stripe, White w/Red Stripe, Green |
| Conductor Material | Copper |
| Conductor Size | 12 AWG |
| Finish | White Paint |
| Gauge | 12 AWG |
| Inside Diameter | 0.386 |
| Insulation Material | THHN/THWN |
| Jacket Material | Interlocked Galvanized Steel Strip |
| Marketing Message (MFR) | Atkore's MC Plus is the modern-day Type MC homerun cable that incorporates a neutral per-phase design ideal for multi-wire branch circuit applications and addresses harmonics distortions in power distribution systems. MC Plus's neutral per-phase design eliminates shared neutrals and the risk of overloading. This design also helps quickly identify faulty circuits, reducing outages. The MC Plus cable offers improved safety and efficiency in electrical systems for a range of applications. |
| Material | Galvanized Steel |
| Number Of Conductors | 4 |
| Outside Diameter | 0.586 IN |
| Product Name | Metal Clad Cable |
| Short Description | 12-2/12-2/12-1 PSST 250C |
| Standard | UL 83, UL 1479, UL 1569, UL 1581, UL 2556, UL File No. E80042, NEC® 210.4(B), 230.43, 300.22(C), 330, 392, 396.10(A), 645, Federal Specifications A-A-59544 (Formerly J-C30B), Meets OSHA and HUD Requirements, Cable Tray Rated, Install per NEC®, UL Classified 1, 2 and 3 Hour Through (Fire Stop) Penetration Product R-14141, Environmental Air Handling Space Installation per NEC® 300.22 |
| Strands | SOL |
| Temperature Rating | 194 |
| Type | Type MC Traditional |
| Weight | 0.2328 LB/FT |
| Wire Length | 250 FT |
Availability
- Akron Qty 250
- Bedford Qty 1500
- Chardon Qty 0
- Cleveland Qty 500
- Lighting Showroom Qty 0
- Macedonia Qty 250
- Mayfield Village (current selection) Qty 5500
- Medina Qty 500
- Middleburg Qty 500
- Streetsboro Qty 250
- Westlake Qty 750
- Willoughby Qty 500
- Youngstown Qty 1250