12/2 MC Cable Hospital Grade 120V 1000 FT Reel

I D P I C v1 mc stat cable

Specifications

Description CABLE HCF-MC-STAT-12/2-120V 1000'**SOLID**5804-60-00
Voltage Rating 600V
Application For branch circuits in areas of patient care in hospitals, nursing homes, outpatient facilities, dental offices, clinics and medical centers (other than emergency, life safety or critical care locations), places of assembly, under raised floors, above suspended ceilings, environmental air-handling spaces, exposed or concealed dry locations, surface mounted, fished, any application requiring isolated or redundant grounding, normal or general purpose power in health care settings
Armour Interlocked Aluminum Strip
Bend Radius 7.845
Catalog Description (MFR) 12-2 Solid Black, White, Green - MC Stat® Lite, Green Interlocked Aluminum Armor with phase ID - Type MCI-A - Health Care Facilities - 1000' Reel
Color Black, White, Green
Conductor Material Copper
Conductor Size 12 AWG
Finish Lime Green Paint
Gauge 12 AWG
Inside Diameter 0.343
Insulation Material THHN
Jacket Material Interlocked Steel/Aluminum Armor
Marketing Message (MFR) MC Stat Lite is a healthcare version of traditional MC Cable, incorporating the redundant ground required for NEC 517.13. The armor in combination with full-sized aluminum ground/bonding conductor, along with the full-sized green insulated copper grounding conductor, provide the necessary grounding redundancy in healthcare settings. MC Stat Lite's unique features, including its wrap-free design, ColorSpecID/ColorTrak ID, and Patented Polypropylene covered THHN/THWN-rated conductors, make it a reliable and efficient choice for healthcare facilities.
Material Aluminum
Number Of Conductors 2
Outside Diameter 0.523 IN
Short Description 12-2 STATAL 1KR
Standard UL 1569, UL 83, UL 1479, UL 1581, UL 2556, UL File No. E80042, Federal Specifications A-A-59544 (Formerly J-C30B), NEC® 330, 300.22(C), 230.43, 250.118, 392, 396, 503, 530, 517, 518, 520, 645, US Patent No. 8088997 B2/8278554 B2, Meets OSHA and HUD Requirements, UL Classified 1, 2, 3 Hour Through (Fire) Penetration Product, R14141, Environmental Air Handling Spaces NEC® 300.22
Strands SOL
Temperature Rating 194
Type Type MC
Weight 0.122 LB/FT
Wire Length 1000 FT

Availability

  • Akron Qty 0
  • Bedford Qty 0
  • Chardon Qty 0
  • Cleveland Qty 0
  • Lighting Showroom Qty 0
  • Macedonia Qty 0
  • Mayfield Village (current selection) Qty 52000
  • Medina Qty 4000
  • Middleburg Qty 0
  • Streetsboro Qty 0
  • Westlake Qty 0
  • Willoughby Qty 0