3/4INX18IN Explosion-Proof Flexible Coupling
3/4INX18IN Explosion-Proof Flexible Coupling
Multiple | ID: 480204
Manufacturer Part Number: EXGJH218

Technical Documents
Specifications
| Description | APP EXGJH218 3/4 EX FLEXIBLE COUP |
| Trade Size | 3/4 x 18IN |
| Application | For areas where vibration or movement is a problem, place of rigid conduit in difficult bend situations, wet locations |
| Catalog Description (MFR) | UNILETS Flexible Coupling, Trade Size: 3/4 IN, Outside Diameter: 1-3/4 IN, Flex Length: 18 IN, Radius: 12 IN Bending, Flexibility: Rigid And IMC, Material: Outer Bronze Braid And Inner Brass Core With Insulating Liner, End Type: (2) Male Nipples |
| Connection | Female Threaded |
| Dimensions | 1-3/4 IN OD x 18 IN L |
| Finish | Natural |
| Flexibility | Rigid And IMC |
| Marketing Message (MFR) | For explosionproof and dust-ignitionproof protection wherever lengths of conduit are joined or connected to an enclosure, count on the quality materials and construction of hazardous location conduit fittings from Appleton Group. We offer sizes, styles and materials to meet any requirement, along with innovative products such as swivel elbows and flexible couplings to simplify challenging installations. We supply the close-up plugs, reducers and other fittings needed to complete any hazardous location installation of threaded rigid metal conduit or IMC. |
| Material | Brass/Bronze |
| Outside Diameter | 1-3/4 |
| Radius | 12, 304.8 |
| Special Features | Accurately tapped, tapered threads for tight, rigid joints and ground continuity;Electrical conductivity equal to rigid conduit on a similar length basis no bonding jumper required;Explosionproof, dust-ignitionproof, watertight;Female end fitting with removable ductile iron union at one end and a female end fitting with a removable brass male nipple at the other end;Heavy duty design resists mechanical abuse;Interior insulating liner protects conductors from abrasion under vibrating conditions;Smooth, rounded integral bushing in each hub protects conductor insulation;Used in areas where vibration and movement is a problem, also used in place of rigid conduit in difficult-bend situations |
| Standard | UL 886, UL 1203 File No. E10444, CSA C22.2 No. 25, CSA C22.2 No. 30, CSA 065181, Class I, Groups A, B, C, D Class II, Groups E, F, G Class III |
| Type | Dust-Ignitionproof Explosionproof Flexible Watertight |
Availability
- Akron Qty 0
- Bedford Qty 0
- Chardon Qty 0
- Cleveland Qty 0
- Lighting Showroom Qty 0
- Macedonia Qty 0
- Mayfield Village (current selection) Qty 4
- Medina Qty 0
- Middleburg Qty 0
- Streetsboro Qty 0
- Westlake Qty 0
- Willoughby Qty 0