Eaton BR816L125FDGP 125 Amp, 16 Circuit, BR Main Lug Load Center, 120/240 Volt, Single-Phase
Eaton BR816L125FDGP 125 Amp, 16 Circuit, BR Main Lug Load Center, 120/240 Volt, Single-Phase
Eaton | ID: 13302
Manufacturer Part Number: BR816L125FDGP

Technical Documents
Specifications
| Description | EATON BR816L125FDGP EATON BR MAINLUG LOADCENTER |
| Amperage Rating | 125 A |
| Voltage Rating | 120/240V |
| Application | Electrical Assemblies, Panels and OEMs Applications |
| Catalog Description (MFR) | Eaton Eaton BR main lug loadcenter,Dual grounds, 125 A,7,Aluminum, NEMA 1,Metallic,10 kAIC,BR,Flush,NEMA 1,16 Circuits,Twenty-four pole,8 Spaces,Three-wire,Single-phase,Type BR 1-inch breakers,120/240V,#14-1 AWG Cu/Al |
| Catalog_Notes | Gbk5 and gbk520 ground bars |
| Certifications | UL 67, UL 50 |
| Cover Type | Cover included |
| Dimensions | 3.56 IN L x 11 IN W x 13 IN H |
| Enclosure Type | NEMA 1 |
| Height | 13 in |
| Includes | Cover |
| Interrupt Rating | 10 kA |
| Marketing Message (MFR) | Specially designed for easy installation, Eaton's BR 1-inch load centers house the branch circuit breakers and the wiring required to distribute power to individual circuits. They serve as main breaker for service entrances or as main lug when adding circuits to existing service. The main breaker protects the entire panel and can be used as a service disconnect. The branch breakers protect the wires leading to individual electrical loads such as fixtures and outlets. |
| Mounting Type | Flush |
| NEMA Rating | 1 |
| Number Of Poles | 16 Pole |
| Number Of Spaces | 8 |
| Phase | 1 Phase |
| Product Feature | BR load centers feature Robertson slotted square combo screwheads, which means only one screwdriver is need for installation., Extra 1.5-inch knock-out for bundling allows maximum wiring gutter space for ease of wiring in compliance with NEC requirements., One-piece roll-formed metal backpan with circuit breaker alignment notches ensures accurately aligned breaker and bus tabs., Plug-on neutral design provides time and labor-savings by eliminating the pigtail., Standard 14-3/8 inches (365.1 mm) wide enclosures fit snugly between wall studs., Tangential main knock-out eliminates the need for conduit offsets, which permits faster, easier installation., Twin neutral design located in wireway, away from circuit breakers, means easier wiring and balancing of the load. |
| Product Name | Eaton BR main lug loadcenter |
| Product Type | Main lug loadcenter |
| Special Features | Dual grounds, current design |
| Standard | UL 67,UL 50 |
| Type | 1-Phase Split |
| Width | 11 in |
| Wire Size | 14 to 1 AWG Cu/Al |
| Wiring Configuration | 3-Wire |