EATON CH2100 TYPE CH BREAKER 100A/2 POLE 120/240V 10K
Eaton

EATON CH2100 TYPE CH BREAKER 100A/2 POLE 120/240V 10K
Eaton | ID: 2830
Manufacturer Part Number: CH2100
Technical Documents
Specifications
Box Quantity | 5 |
American Recovery and Reinvestment Act (ARRA) Compliant | C |
Amperage Rating | 100 A |
Application | OtherMarine Vessels and Equipment - Marine Vessels and Equipment - OtherGeneration - Renewable Energy - Alternative EnergyGeneration - Conventional Energy - Conventional EnergyDatacenters - IT Space: CI and Hyper Converged |
Brand Name | Eaton |
Buy American Act (BAA) Compliant | C |
Catalog Description (MFR) | Eaton CH Thermal magnetic circuit breaker, Type CH 3/4-Inch standard circuit breaker, 100 A, 10 kAIC, Two-pole, 120/240V, CH, Common breaker trip, 14AWG 1/0AWG, u/Al, CH, Type CH Loadcenters |
Catalog_Notes | Two-Pole 120/240VCommon Trip Requires Two3/4-Inch Spaces |
Certifications | UL 489 |
Commodity Code | 3310 |
Concatenated Invoice Description | Type CH Breaker 100A/2 Pole 120/240V 10K |
Description | EATON CH2100 TYPE CH BREAKER 100A/2 POLE 120/240V 10K |
Ean | 4015081220359 |
Interrupt Rating | 10 kAIC |
Invoice Description (MFR) | Type CH Breaker 100A/2 Pole 120/240V 10K |
Marketing Message (MFR) | Eaton's residential CH circuit breakers provide premium overload protection. The Type CH circuit breakers trip to the OFF position, eliminating nuisance callbacks. The CHF family also includes a trip flag to differentiate between a trip and the breaker being turned off. The thermal-magnetic trip curve avoids nuisance tripping on mild overloads while reacting almost instantaneously to severe short-circuit conditions. Multiple breakers have an internal common trip connection to operate all poles simultaneously. Handles are marked with ON-OFF indication and ampere rating of the breaker. |
Number Of Poles | 2 Pole |
Product Feature | Standard LED indicates one of seven trip codes to simplify circuit diagnostics., GFCI, One pole breakers 15–30A, Plug-on neutral, Trip codes are stored permanently into the breaker’s memory, to help identify “trip” history, Time savings up to 25% per AFCI and GFCI installation, Eliminates unwanted tripping due to loose pigtail connections, Improved wireway access, Meets areas requiring AFCI protection under the 200 and all subsequent edition of the NEC., Limited lifetime warranty on all CH products, GFCI: One pole breakers 15–30A 5mA protection per UL943, Plug-on neutral: Time savings up to 25% per AFCI and GFCI installation Improved wireway access Easier troubleshooting due to less wiring Eliminates unwanted tripping due to loose pigtail connections Limited lifetime warranty on all CH products, AFCI: Advanced electronics to reduce unwanted tripping from non-compliant devices. Standard LED indicates one of seven trip codes to simplify circuit diagnostics. Trip codes are stored permanently into the breaker’s memory, to help identify “trip” history. Branch overvoltage protection for sensitive electronics. Meets areas requiring AFCI protection under the 200 and all subsequent edition of the NEC. |
Product Name | Eaton CH thermal magnetic circuit breaker |
Product Type | Thermal magnetic circuit breakers |
Safety Data Sheet (SDS) Flag | N |
Standard | UL 489 |
Stripped Catalog Number | CH2100 |
Trip Type | Common breaker trip |
Type | Thermal magnetic circuit breakers |
UNSPSC | 39121601 |
Voltage Rating | 120/240V |
Availability
- Akron Qty 0
- Bedford Qty 0
- Chardon Qty 0
- Cleveland Qty 0
- Lighting Showroom Qty 0
- Macedonia Qty 0
- Mayfield Village (current selection) Qty 3
- Medina Qty 0
- Middleburg Qty 0
- Streetsboro Qty 0
- Westlake Qty 0
- Willoughby Qty 0
Recently Viewed Products
Loading recently viewed products...
You May Also Like