Eaton CH270 CH, 2 Pole, 70 Amp, Plug-On Circuit Breaker, 120/240 Volt
Eaton CH270 CH, 2 Pole, 70 Amp, Plug-On Circuit Breaker, 120/240 Volt
Eaton | ID: 10745
Manufacturer Part Number: CH270

Technical Documents
Specifications
| Description | EATON CH270 TYPE CH BREAKER 70A/2POLE 120/240V 10K |
| Amperage Rating | 70 A |
| Voltage Rating | 120/240V |
| Actuator | 2-Position Handle |
| Application | Marine Vessels and Equipment - Marine Vessels and Equipment - OtherOtherGeneration - Renewable Energy - Alternative EnergyDatacenters - IT Space: CI and Hyper ConvergedGeneration - Conventional Energy - Conventional Energy |
| Catalog Description (MFR) | Eaton CH thermal magnetic circuit breker,Type CH 3/4-Inch standard circuit breaker,70 A,10 kAIC,Two-pole,120/240V,CH,Common breaker trip,#14-2 AWG Cu/Al,CH,Type CH Loadcenters |
| Catalog_Notes | Two-Pole 120/240V Common Trip Requires Two 3/4-Inch Spaces |
| Certifications | UL 489 |
| Color | Black |
| Dimensions | 3/4 IN W x 3-1/2 IN D x 3 IN H |
| Enclosure Type | NEMA 1/3R |
| Interrupt Rating | 10 kA |
| Marketing Message (MFR) | Eaton's residential CH circuit breakers provide premium overload protection. The Type CH circuit breakers trip to the OFF position, eliminating nuisance callbacks. The CHF family also includes a trip flag to differentiate between a trip and the breaker being turned off. The thermal-magnetic trip curve avoids nuisance tripping on mild overloads while reacting almost instantaneously to severe short-circuit conditions. Multiple breakers have an internal common trip connection to operate all poles simultaneously. Handles are marked with ON-OFF indication and ampere rating of the breaker. |
| Material | Bakelite |
| Mounting Type | Plug-On |
| Number Of Poles | 2 Pole |
| Phase | 1 |
| Product Feature | AFCI:Advanced electronics to reduce unwanted tripping from non-compliant devices.Standard LED indicates one of seven trip codes to simplify circuit diagnostics.Trip codes are stored permanently into the breaker’s memory, to help identify “trip” history.Branch overvoltage protection for sensitive electronics.Meets areas requiring AFCI protection under the 200 and all subsequent edition of the NEC., Eliminates unwanted tripping due to loose pigtail connections, GFCI, GFCI:One pole breakers 15–30A5mA protection per UL943, Improved wireway access, Limited lifetime warranty on all CH products, Meets areas requiring AFCI protection under the 200 and all subsequent edition of the NEC., One pole breakers 15–30A, Plug-on neutral, Plug-on neutral: Time savings up to 25% per AFCI and GFCI installationImproved wireway accessEasier troubleshooting due to less wiringEliminates unwanted tripping due to loose pigtail connectionsLimited lifetime warranty on all CH products, Standard LED indicates one of seven trip codes to simplify circuit diagnostics., Time savings up to 25% per AFCI and GFCI installation, Trip codes are stored permanently into the breaker’s memory, to help identify “trip” history |
| Product Name | Eaton CH thermal magnetic circuit breaker |
| Product Type | Thermal magnetic circuit breakers |
| Standard | UL 489 |
| Trip Type | Thermal Magnetic |
| Type | Type CH Standard |
| Wire Size | 14 to 2 AWG |
Availability