EATON CHF115 TYPE CHF BREAKER 15A / 1P 120/240V 10 KA

Chf115 r 300x300 300dpi

Specifications

American Recovery and Reinvestment Act (ARRA) Compliant C
Amperage Rating 15 A
Application Generation - Conventional Energy - Conventional EnergyOtherDatacenters - IT Space: CI and Hyper ConvergedMarine Vessels and Equipment - Marine Vessels and Equipment - OtherGeneration - Renewable Energy - Alternative Energy
Brand Name Eaton
Buy American Act (BAA) Compliant C
Catalog Description (MFR) Eaton CH Thermal magnetic circuit breaker, Type CHF 3/4-Inch standard circuit breaker, 15 A, 10 kAIC, Single-pole, 120/240V, CHF, Trip flag, common breaker trip, (1) #14-8 AWG, (2) #14-10 AWG Cu/Al, CHF, Type CH Loadcenters
Catalog_Notes Switching Duty Rated, HACR Rated, Single-Pole Requires One 2/4-Inch Space, With Trip Indication.
Certifications UL 489
Compliances HACR Rated
Concatenated Invoice Description TYPE CHF BREAKER 15A / 1P 120/240V 10 KA
Description EATON CHF115 TYPE CHF BREAKER 15A / 1P 120/240V 10 KA
Ean 4015082844004
Interrupt Rating 10 kAIC
Invoice Description (MFR) TYPE CHF BREAKER 15A / 1P 120/240V 10 KA
Marketing Message (MFR) Eaton's residential CH circuit breakers provide premium overload protection. The Type CH circuit breakers trip to the OFF position, eliminating nuisance callbacks. The CHF family also includes a trip flag to differentiate between a trip and the breaker being turned off. The thermal-magnetic trip curve avoids nuisance tripping on mild overloads while reacting almost instantaneously to severe short-circuit conditions. Multiple breakers have an internal common trip connection to operate all poles simultaneously. Handles are marked with ON-OFF indication and ampere rating of the breaker.
Number Of Poles 1 Pole
Product Feature GFCI, AFCI: Advanced electronics to reduce unwanted tripping from non-compliant devices. Standard LED indicates one of seven trip codes to simplify circuit diagnostics. Trip codes are stored permanently into the breaker’s memory, to help identify “trip” history. Branch overvoltage protection for sensitive electronics. Meets areas requiring AFCI protection under the 200 and all subsequent edition of the NEC., GFCI: One pole breakers 15–30A 5mA protection per UL943, Plug-on neutral:  Time savings up to 25% per AFCI and GFCI installation Improved wireway access Easier troubleshooting due to less wiring Eliminates unwanted tripping due to loose pigtail connections Limited lifetime warranty on all CH products, One pole breakers 15–30A, Plug-on neutral, Standard LED indicates one of seven trip codes to simplify circuit diagnostics., Trip codes are stored permanently into the breaker’s memory, to help identify “trip” history, Time savings up to 25% per AFCI and GFCI installation, Eliminates unwanted tripping due to loose pigtail connections, Improved wireway access, Meets areas requiring AFCI protection under the 200 and all subsequent edition of the NEC., Limited lifetime warranty on all CH products
Product Name Eaton CH thermal magnetic circuit breaker
Product Type Thermal magnetic circuit breakers
Safety Data Sheet (SDS) Flag N
Standard UL 489,HACR Rated
Stripped Catalog Number CHF115
Trip Type Trip flag
Type Thermal magnetic circuit breakers
UNSPSC 39121601
Voltage Rating 120/240V

Availability

  • Akron Qty 11
  • Bedford Qty 0
  • Chardon Qty 0
  • Cleveland Qty 0
  • Lighting Showroom Qty 0
  • Macedonia Qty 0
  • Mayfield Village (current selection) Qty 53
  • Medina Qty 1
  • Middleburg Qty 0
  • Streetsboro Qty 0
  • Westlake Qty 2
  • Willoughby Qty 0
  • Youngstown Qty 10

Recently Viewed Products

Loading recently viewed products...

You May Also Like

Loading product details...