Eaton CHF230 CH, 2 Pole, 30 Amp, Plug-On Circuit Breaker, 120/240 Volt
Eaton CHF230 CH, 2 Pole, 30 Amp, Plug-On Circuit Breaker, 120/240 Volt
Eaton | ID: 10047
Manufacturer Part Number: CHF230
Technical Documents
Specifications
Box Quantity | 5 |
American Recovery and Reinvestment Act (ARRA) Compliant | C |
Amperage Rating | 30 A |
Application | Datacenters - IT Space: CI and Hyper ConvergedOtherGeneration - Renewable Energy - Alternative EnergyGeneration - Conventional Energy - Conventional EnergyMarine Vessels and Equipment - Marine Vessels and Equipment - Other |
Brand Name | Eaton |
Buy American Act (BAA) Compliant | C |
Catalog Description (MFR) | Eaton CH Thermal magnetic circuit breaker, Type CHF 3/4-Inch standard circuit breaker, 30 A, 10 kAIC, Two-pole, 120/240V, CHF, Trip flag, common breaker trip, (1) #14-8 AWG, (2) #14-10 AWG Cu/Al, CHF, Type CH Loadcenters |
Catalog_Notes | HACR Rated. Two-Pole 120/240V Common Trip Requires Two 3/4-Inch Spaces. With Trip Indication |
Certifications | UL 489 |
Commodity Code | 3310 |
Compliances | HACR Rated |
Concatenated Invoice Description | CHF BREAKER 30A / 2P 120/240V 10 KAIC |
Description | EATON CHF230 TYPE CHF BREAKER 30A / 2P 120/240V 10 KA |
Ean | 4015082245504 |
Interrupt Rating | 10 kAIC |
Invoice Description (MFR) | CHF BREAKER 30A / 2P 120/240V 10 KAIC |
Marketing Message (MFR) | Eaton's residential CH circuit breakers provide premium overload protection. The Type CH circuit breakers trip to the OFF position, eliminating nuisance callbacks. The CHF family also includes a trip flag to differentiate between a trip and the breaker being turned off. The thermal-magnetic trip curve avoids nuisance tripping on mild overloads while reacting almost instantaneously to severe short-circuit conditions. Multiple breakers have an internal common trip connection to operate all poles simultaneously. Handles are marked with ON-OFF indication and ampere rating of the breaker. |
Number Of Poles | 2 Pole |
Product Feature | GFCI, AFCI: Advanced electronics to reduce unwanted tripping from non-compliant devices. Standard LED indicates one of seven trip codes to simplify circuit diagnostics. Trip codes are stored permanently into the breaker’s memory, to help identify “trip” history. Branch overvoltage protection for sensitive electronics. Meets areas requiring AFCI protection under the 200 and all subsequent edition of the NEC., GFCI: One pole breakers 15–30A 5mA protection per UL943, Plug-on neutral: Time savings up to 25% per AFCI and GFCI installation Improved wireway access Easier troubleshooting due to less wiring Eliminates unwanted tripping due to loose pigtail connections Limited lifetime warranty on all CH products, One pole breakers 15–30A, Plug-on neutral, Standard LED indicates one of seven trip codes to simplify circuit diagnostics., Trip codes are stored permanently into the breaker’s memory, to help identify “trip” history, Time savings up to 25% per AFCI and GFCI installation, Eliminates unwanted tripping due to loose pigtail connections, Improved wireway access, Meets areas requiring AFCI protection under the 200 and all subsequent edition of the NEC., Limited lifetime warranty on all CH products |
Product Name | Eaton CH thermal magnetic circuit breaker |
Product Type | Thermal magnetic circuit breakers |
Safety Data Sheet (SDS) Flag | N |
Standard | UL 489,HACR Rated |
Stripped Catalog Number | CHF230 |
Trip Type | Trip flag |
Type | Thermal magnetic circuit breakers |
UNSPSC | 39121601 |
Voltage Rating | 120/240V |
Availability
- Akron Qty 15
- Bedford Qty 0
- Chardon Qty 0
- Cleveland Qty 0
- Lighting Showroom Qty 0
- Macedonia Qty 0
- Mayfield Village (current selection) Qty 12
- Medina Qty 3
- Middleburg Qty 2
- Streetsboro Qty 2
- Westlake Qty 1
- Willoughby Qty 1
- Youngstown Qty 11