Eaton CHF250 CH, 2 Pole, 50 Amp, Plug-On Circuit Breaker, 120/240 Volt

C H F250 L (1000x1000 300dpi)

Technical Documents

Specifications

Description EATON CHF250 TYPE CHF BREAKER, 50A/ 2P 120/240V 10KA
Amperage Rating 50 A
Voltage Rating 120/240V
Actuator Toggle Handle
Application Generation, Renewable Energy, Alternative Energy, Conventional Energy, Conventional Energy, Datacenters, CI and Hyper Converged IT Space, Marine Vessels and Equipment
Catalog Description (MFR) Eaton CH Thermal magnetic circuit breaker, Type CHF 3/4-Inch standard circuit breaker, 50 A, 10 kAIC, Two-pole, 120/240V, CHF, Trip flag, common breaker trip, #10-1/0 AWG Cu/Al, CHF, Type CH Loadcenters
Catalog_Notes HACR Rated. Two-Pole 120/240V Common Trip Requires Two 3/4-Inch Spaces. With Trip Indication
Certifications UL 489
Compliances HACR Rated
Dimensions 3 IN L x 3/4 IN W x 3 IN H
Interrupt Rating 10 kAIC
Marketing Message (MFR) Eaton's residential CH circuit breakers provide premium overload protection. The Type CH circuit breakers trip to the OFF position, eliminating nuisance callbacks. The CHF family also includes a trip flag to differentiate between a trip and the breaker being turned off. The thermal-magnetic trip curve avoids nuisance tripping on mild overloads while reacting almost instantaneously to severe short-circuit conditions. Multiple breakers have an internal common trip connection to operate all poles simultaneously. Handles are marked with ON-OFF indication and ampere rating of the breaker.
Mounting Type Plug-On
Number Of Poles 2 Pole
Phase 1
Product Feature AFCI:Advanced electronics to reduce unwanted tripping from non-compliant devices.Standard LED indicates one of seven trip codes to simplify circuit diagnostics.Trip codes are stored permanently into the breaker’s memory, to help identify “trip” history.Branch overvoltage protection for sensitive electronics.Meets areas requiring AFCI protection under the 200 and all subsequent edition of the NEC., Eliminates unwanted tripping due to loose pigtail connections, GFCI, GFCI:One pole breakers 15–30A5mA protection per UL943, Improved wireway access, Limited lifetime warranty on all CH products, Meets areas requiring AFCI protection under the 200 and all subsequent edition of the NEC., One pole breakers 15–30A, Plug-on neutral, Plug-on neutral: Time savings up to 25% per AFCI and GFCI installationImproved wireway accessEasier troubleshooting due to less wiringEliminates unwanted tripping due to loose pigtail connectionsLimited lifetime warranty on all CH products, Standard LED indicates one of seven trip codes to simplify circuit diagnostics., Time savings up to 25% per AFCI and GFCI installation, Trip codes are stored permanently into the breaker’s memory, to help identify “trip” history
Product Name Eaton CH thermal magnetic circuit breaker
Product Type Thermal magnetic circuit breakers
Standard UL 489,HACR Rated
Trip Type Trip flag
Type Type CHF Standard
Wire Size 10 to 1/0 AWG Copper/Aluminum

Availability

  • Akron Qty 2
  • Bedford Qty 20
  • Chardon Qty 0
  • Cleveland Qty 0
  • Lighting Showroom Qty 0
  • Macedonia Qty 2
  • Mayfield Village (current selection) Qty 137
  • Medina Qty 3
  • Middleburg Qty 0
  • Streetsboro Qty 2
  • Westlake Qty 2
  • Willoughby Qty 0
  • Youngstown Qty 5