GE SAST1 120VAC SHUNT TRIP
Technical Documents
Specifications
American Recovery and Reinvestment Act (ARRA) Compliant | C |
Buy American Act (BAA) Compliant | C |
Catalog Description (MFR) | All Spectra RMS circuit breakers from the SE150 through the SK1200, including instantaneous trip Mag-Break motor circuit protectors and molded case switches, use the same UL listed field-installable internal accessories that do not require cover removal to install. Shunt trip provides remote tripping of the breaker when used with a momentary close contact. Not recommended for use with a latching relay contact since electronics in the shunt trip will pulse power to the coil if continuously energized, and breaker shunt tripping upon reclosure will be delayed 1-2 seconds at rated control voltage. (A short circuit trip would be instantaneous.) If maintained (latching relay) contact must be used and delayed shunt tripping is not acceptable, use bell alarm in series with control power for SE150 and SF250 frames and auxiliary switch for SG600 and SK1200 breakers. These devices are suitable for use with ground fault sensing and relaying equipment. Maximum VA is 75. AC devices are UL listed for 50-60 Hz. SAST1 |
Commodity Code | 3290 |
Concatenated Invoice Description | SHUNT TRIP ASM 120 AC |
Description | GE SAST1 120VAC SHUNT TRIP |
Invoice Description (MFR) | SHUNT TRIP ASM 120 AC |
Product Name | Circuit Breaker Shunt Trip |
Special Features | All Spectra RMS circuit breakers from the SE150 through the SK1200, including instantaneous trip Mag-Break motor circuit protectors and molded case switches, use the same UL listed field-installable internal accessories that do not require cover removal to install. Shunt trip provides remote tripping of the breaker when used with a momentary close contact. Not recommended for use with a latching relay contact since electronics in the shunt trip will pulse power to the coil if continuously energized, and breaker shunt tripping upon reclosure will be delayed 1-2 seconds at rated control voltage. (A short circuit trip would be instantaneous.) If maintained (latching relay) contact must be used and delayed shunt tripping is not acceptable, use bell alarm in series with control power for SE150 and SF250 frames and auxiliary switch for SG600 and SK1200 breakers. These devices are suitable for use with ground fault sensing and relaying equipment. Maximum VA is 75. AC devices are UL listed for 50-60 Hz. SAST1 |
Standard | E57253 |
Stripped Catalog Number | SAST1 |
Sub Brand | Spectra RMS |
UNSPSC | 39121601 |
Voltage Rating | 120V |
Availability
- Akron Qty 0
- Bedford Qty 0
- Chardon Qty 0
- Cleveland Qty 0
- Lighting Showroom Qty 0
- Macedonia Qty 0
- Mayfield Village (current selection) Qty 15
- Medina Qty 0
- Middleburg Qty 0
- Streetsboro Qty 0
- Westlake Qty 0
- Willoughby Qty 0
Recently Viewed Products
Loading recently viewed products...
You May Also Like
Loading product details...