Mersen A2D150R 150 Amp, 250 Volt, Class RK1 Time Delay Fuse

0f4b7f62f628498bb0c95dd71b932270 2

Specifications

Alternate Catalog Number A2D150R
American Recovery and Reinvestment Act (ARRA) Compliant X
Amperage Rating 150 A
Application Motors Safety switches Transformers Branch circuit protection Disconnects Control panels All general-purpose circuits
Brand Name Mersen
Buy American Act (BAA) Compliant X
Catalog Description (MFR) Amp-Trap 2000 SmartSpot time-delay A2D-R fuses provide IEC Type 2 "no damage" protection to existing mains, feeders, and branch circuits serving motor and non-motor loads. A2D-R fuses will open fast enough under extreme fault conditions for maximum short circuit protection to prevent damage to motor starters, switches, and other circuit components, yet also provide the time-delay needed for motor in-rush currents. A2D-R fuses can be used to replace 250V Class H, K or RK5 fuses already installed in the field. 250 Volts 150 amps.
Class Class RK1
Commodity Code 6113
Concatenated Invoice Description Fuse A2D-R - Class RK1 - Time-Delay 250V
Connection Blade
Description MFZ A2D150R 250V RK1 TD FUSE
Fuse Type Time Delay
Interrupt Rating 200 kA
Invoice Description (MFR) Fuse A2D-R - Class RK1 - Time-Delay 250VAC 250VDC 150A Blade SmartSpot
Marketing Message (MFR) Amp-Trap 2000 time-delay A2D-R fuses provide IEC Type 2 "no damage" protection to existing mains, feeders, and branch circuits serving motor and non-motor loads. A2D-R fuses will open fast enough under extreme fault conditions for maximum short circuit protection to prevent damage to motor starters, switches, and other circuit components, yet also provide the time-delay needed for motor in-rush currents. A2D-R fuses can be used to replace older 250V Class H, K or RK5 fuses already installed in the field.
Mounting Clip
Product Name Low Voltage UL Power Fuse
Safety Data Sheet (SDS) Flag N
Shipping Restrictions (MFR) No Shipping Restrictions
Short Description 250V 150A RK1 TD FUSE
Size 7.13 x 1.56 in
Special Features Non-indicating or Solid state SmartSpot visual blown fuse indicator Time-delay for motor starting and transformer inrush currents without nuisance opening 600VAC & 600VDC dual rated 300kA interrupting rating - self-certified, UL witnessed tests Extremely current-limiting for low peak let-thru current Recommended for Arc Flash energy reduction Easy 2-to-1 selectivity for prevention of nuisance shut downs and black outs Rejection-style design prevents replacement errors (when used with recommended fuse blocks) High-visibility orange label gives instant brand recognition Reduced inventory by taking the place of class RK5, K, and H fuses Metal-embossed date and catalog number for easier traceability and lasting identification Fiberglass body provides dimensional stability in harsh industrial settings
Standard UL listed to standard 248-12 File E2137 DC listed to UL standard 248 CSA certified to standard C22.2 No. 248.12
Stripped Catalog Number A2D150R
Sub Brand Amp-Trap 2000
Substitutes 637427
Type Class RK1
Type Of Indicators SmartSpot
UNSPSC 39121604
Voltage Rating 250V

Availability

  • Akron Qty 0
  • Bedford Qty 0
  • Chardon Qty 0
  • Cleveland Qty 0
  • Lighting Showroom Qty 0
  • Macedonia Qty 0
  • Mayfield Village (current selection) Qty 0
  • Medina Qty 0
  • Middleburg Qty 0
  • Streetsboro Qty 0
  • Westlake Qty 0
  • Willoughby Qty 0
  • Youngstown Qty 0

Recently Viewed Products