Mersen A2D200R 200 Amp, 250 Volt, Class RK1 Time Delay Fuse

8ee321647cac47ce97e07793ab2f50a9 2

Specifications

Description MFZ A2D200R 250V RK1 TD FUSE
Amperage Rating 200 A
Voltage Rating 250V
Application Motor, Safety Switches, Transformers, Disconnects, Control Panel and All General Purpose Circuits Applications
Catalog Description (MFR) Fuse A2D-R - Class RK1 - Time-Delay 250VAC 250VDC 200A Blade SmartSpot® Amp-Trap 2000®
Certifications CSA, UL
Class Class RK1
Connection Blade
Fuse Type Time Delay
Interrupt Rating 200 kA
Marketing Message (MFR) Amp-Trap 2000 time-delay A2D-R fuses provide IEC Type 2 "no damage" protection to existing mains, feeders, and branch circuits serving motor and non-motor loads. A2D-R fuses will open fast enough under extreme fault conditions for maximum short circuit protection to prevent damage to motor starters, switches, and other circuit components, yet also provide the time-delay needed for motor in-rush currents. A2D-R fuses can be used to replace older 250V Class H, K or RK5 fuses already installed in the field.
Material Fiberglass
Mounting Type Clip
Product Name Low Voltage UL Power Fuse
Shipping Restrictions (MFR) No Shipping Restrictions
Short Description 250V 200A RK1 TD FUSE
Special Features Non-indicating or Solid state SmartSpot visual blown fuse indicator Time-delay for motor starting and transformer inrush currents without nuisance opening 600VAC & 600VDC dual rated 300kA interrupting rating - self-certified, UL witnessed tests Extremely current-limiting for low peak let-thru current Recommended for Arc Flash energy reduction Easy 2-to-1 selectivity for prevention of nuisance shut downs and “black outs” Rejection-style design prevents replacement errors (when used with recommended fuse blocks) High-visibility orange label gives instant brand recognition Reduced inventory by taking the place of class RK5, K, and H fuses Metal-embossed date and catalog number for easier traceability and lasting identification Fiberglass body provides dimensional stability in harsh industrial settings
Standard CSA C22.2 No. 248.12, RoHS Compliant, UL 248-12 File No. E2137
Type Current Limiting Low Voltage North American Time Delay
Type Of Indicators SmartSpot®

Availability

  • Akron Qty 0
  • Bedford Qty 0
  • Chardon Qty 0
  • Cleveland Qty 0
  • Lighting Showroom Qty 0
  • Macedonia Qty 0
  • Mayfield Village (current selection) Qty 0
  • Medina Qty 0
  • Middleburg Qty 0
  • Streetsboro Qty 0
  • Westlake Qty 0
  • Willoughby Qty 0
  • Youngstown Qty 0

Recently Viewed Products

Loading recently viewed products...

You May Also Like

Loading product details...