Mersen A4BQ1600 1600 Amp, 600 Volt, Class L Time Delay Fuse

2ff05740a2f04b35b404ddda6ae5a7fe 2

Specifications

Description MFZ A4BQ1600 600V CLASS L FUSE
Amperage Rating 1600 A
Voltage Rating 600V
Application Mains, Feeders, Large Motors, Lighting, Heating and General Loads, Circuit Breaker Back-Up, UPS and Battery Circuits Applications
Catalog Description (MFR) Fuse A4BQ - Class L - Time-Delay 600VAC 500VDC 1600A Blade Amp-Trap 2000®
Certifications CSA, UL
Class Class L
Connection Blade
Fuse Type Time Delay
Interrupt Rating 200 kA
Marketing Message (MFR) Amp-Trap 2000 A4BQ fuses are 20 percent more current limiting than any other Class L fuse on the market. When correctly coordinated, they bring a superior level of protection to service entrance equipment. Downstream circuit components have maximum protection against short circuit let-thru current. A4BQ's built-in 4-second time-delay characteristic (at 500percent of rated current) accommodates harmless inrush currents with no nuisance opening.
Material Fiberglass
Mounting Type Bolted-On
Product Name Low Voltage UL Power Fuse
Response Time 4 s at 500%
Shipping Restrictions (MFR) No Shipping Restrictions
Short Description L TD FUSE 600V 1600A A4BQ
Special Features Fastest operation under short circuit conditions: Let-thru currents are typically 20 percent lower, with a corresponding let-thru energy (clearing I2t) up to 40 lower than the next fastest Class L fuse Time-delay for high inrush loads such as motors and transformers, without nuisance opening 300kA interrupting rating - self-certified, UL witnessed tests Most current-limiting for lowest peak let-thru current even at fault currents up to 300kA Recommended for Arc Flash energy reduction Pure silver links ensure lowest let-thru current and longer fuse life Easy 2-to-1 selectivity for prevention of nuisance shutdowns and “blackouts” Rejection-style design prevents replacement errors High-visibility orange label gives instant brand recognition Reduced inventory because A4BQ can replace all older types of Class L fuses now in-service Metal-embossed date and catalog number for traceability and lasting identification Fiberglass body provides dimensional stability in harsh industrial settings High-grade silica filler ensures fast arc quenching Optional mechanical TA indicator (100-6000A). Please contact factory for special trigger actuator
Standard CSA C22.2 No. 248.10, DC Listed, RoHS Compliant, UL 248, UL 248-10 File No. E2137
Type Current Limiting Low Voltage North American Time Delay

Availability

  • Akron Qty 0
  • Bedford Qty 0
  • Chardon Qty 0
  • Cleveland Qty 0
  • Lighting Showroom Qty 0
  • Macedonia Qty 0
  • Mayfield Village (current selection) Qty 3
  • Medina Qty 0
  • Middleburg Qty 0
  • Streetsboro Qty 0
  • Westlake Qty 0
  • Willoughby Qty 0
  • Youngstown Qty 0

Recently Viewed Products

Loading recently viewed products...