Mersen A6D35R 600V RK1 TD FUSE

0d7fb18d97c040238a7b76837b61c149 2

Specifications

Box Quantity 10
Alternate Catalog Number A6D35R
American Recovery and Reinvestment Act (ARRA) Compliant X
Amperage Rating 35 A
Application Motors Safety switches Transformers Branch circuit protection Disconnects Control panels All general-purpose circuits
Brand Name Mersen
Buy American Act (BAA) Compliant X
Catalog Description (MFR) Amp-Trap 2000 SmartSpot time-delay A6D-R fuses provide IEC Type 2 "no damage" protection to existing mains, feeders, and branch circuits serving motor and non-motor loads. A6D-R fuses will open fast enough under extreme fault conditions for maximum short circuit protection to prevent damage to motor starters, switches, and other circuit components, yet also provide the time-delay needed for motor in-rush currents. A6D-R fuses can be used to replace 600V Class H, K or RK5 fuses already installed in the field. 600 Volts 35 amps.
Class Class RK1
Commodity Code 6113
Concatenated Invoice Description Fuse A6D-R - Class RK1 - Time-Delay 600V
Connection Ferrule
Description MFZ A6D35R 600V RK1 TD FUSE
Interrupt Rating 200 kA
Invoice Description (MFR) Fuse A6D-R - Class RK1 - Time-Delay 600VAC 600VDC 35A Ferrule SmartSpot
Marketing Message (MFR) Amp-Trap 2000 time-delay A6D-R fuses provide IEC Type 2 "no damage" protection to existing mains, feeders, and branch circuits serving motor and non-motor loads. A6D-R fuses will open fast enough under extreme fault conditions for maximum short circuit protection to prevent damage to motor starters, switches, and other circuit components, yet also provide the time-delay needed for motor in-rush currents. A6D-R fuses can be used to replace older 600V Class H, K or RK5 fuses already installed in the field.
Mounting Clip
Product Name Low Voltage UL Power Fuse
Safety Data Sheet (SDS) Flag N
Shipping Restrictions (MFR) No Shipping Restrictions
Short Description 600V 35A RK1 TD FUSE
Size 5.5 x 1.06 in
Special Features Non-indicating or Solid state SmartSpot visual blown fuse indicator Time-delay for motor starting and transformer inrush currents without nuisance opening 600VAC & 600VDC dual rated 300kA interrupting rating - self-certified, UL witnessed tests Extremely current-limiting for low peak let-thru current Recommended for Arc Flash energy reduction Easy 2-to-1 selectivity for prevention of nuisance shut downs and black outs Rejection-style design prevents replacement errors (when used with recommended fuse blocks) High-visibility orange label gives instant brand recognition Reduced inventory by taking the place of class RK5, K, and H fuses Metal-embossed date and catalog number for easier traceability and lasting identification Fiberglass body provides dimensional stability in harsh industrial settings
Standard UL listed to standard 248-12 File E2137 DC listed to UL standard 248 CSA certified to standard C22.2 No. 248.12
Stripped Catalog Number A6D35R
Sub Brand Amp-Trap 2000
Type Class RK1
Type Of Indicators SmartSpot
UNSPSC 39121604
Voltage Rating 600V

Availability

  • Akron Qty 0
  • Bedford Qty 0
  • Chardon Qty 0
  • Cleveland Qty 0
  • Lighting Showroom Qty 0
  • Macedonia Qty 0
  • Mayfield Village (current selection) Qty 3
  • Medina Qty 0
  • Middleburg Qty 0
  • Streetsboro Qty 0
  • Westlake Qty 0
  • Willoughby Qty 0
  • Youngstown Qty 0

Recently Viewed Products

Loading recently viewed products...

You May Also Like

Loading product details...