Description MFZ A6D60R 600V RK1 TD FUSE
Amperage Rating 60 A
Voltage Rating 600V
Application Motor, Safety Switches, Transformers, Disconnects, Control Panel and All General Purpose Circuits Applications
Catalog Description (MFR) Fuse A6D-R - Class RK1 - Time-Delay 600VAC 600VDC 60A Ferrule SmartSpot® Amp-Trap 2000®
Class Class RK1
Connection Ferrule
Fuse Type Time Delay
Interrupt Rating 200 kA
Marketing Message (MFR) Amp-Trap 2000 time-delay A6D-R fuses provide IEC Type 2 "no damage" protection to existing mains, feeders, and branch circuits serving motor and non-motor loads. A6D-R fuses will open fast enough under extreme fault conditions for maximum short circuit protection to prevent damage to motor starters, switches, and other circuit components, yet also provide the time-delay needed for motor in-rush currents. A6D-R fuses can be used to replace older 600V Class H, K or RK5 fuses already installed in the field.
Material Fiberglass
Mounting Type Clip
Product Name Low Voltage UL Power Fuse
Shipping Restrictions (MFR) No Shipping Restrictions
Short Description 600V 60A RK1 TD FUSE
Special Features Non-indicating or Solid state SmartSpot visual blown fuse indicator Time-delay for motor starting and transformer inrush currents without nuisance opening 600VAC & 600VDC dual rated 300kA interrupting rating - self-certified, UL witnessed tests Extremely current-limiting for low peak let-thru current Recommended for Arc Flash energy reduction Easy 2-to-1 selectivity for prevention of nuisance shut downs and “black outs” Rejection-style design prevents replacement errors (when used with recommended fuse blocks) High-visibility orange label gives instant brand recognition Reduced inventory by taking the place of class RK5, K, and H fuses Metal-embossed date and catalog number for easier traceability and lasting identification Fiberglass body provides dimensional stability in harsh industrial settings
Standard CSA C22.2 No. 248.12, DC Listed, UL 248, UL 248-12 File No. E2137
Type Current Limiting Low Voltage North American Time Delay
Type Of Indicators SmartSpot®

Availability

  • Akron Qty 0
  • Bedford Qty 0
  • Chardon Qty 0
  • Cleveland Qty 0
  • Lighting Showroom Qty 0
  • Macedonia Qty 0
  • Mayfield Village (current selection) Qty 15
  • Medina Qty 0
  • Middleburg Qty 0
  • Streetsboro Qty 0
  • Westlake Qty 0
  • Willoughby Qty 0
  • Youngstown Qty 0

Recently Viewed Products

Loading recently viewed products...

You May Also Like

Loading product details...