Mersen TR7R 7 Amp, 250 Volt, Class RK5 Time Delay Fuse
Mersen TR7R 7 Amp, 250 Volt, Class RK5 Time Delay Fuse
Mersen | ID: 13298
Manufacturer Part Number: TR7R
Technical Documents
Specifications
Alternate Catalog Number | TR7R |
American Recovery and Reinvestment Act (ARRA) Compliant | X |
Amperage Rating | 7 A |
Application | Motor circuits Mains Feeders Branch circuits Transformers Service entrance equipment General-purpose equipment |
Brand Name | Mersen |
Buy American Act (BAA) Compliant | X |
Catalog Description (MFR) | Fuse TR-R - Class RK5 - Time-Delay 250VAC 160VDC 7A Ferrule Tri-Onic® |
Class | Class RK5 |
Commodity Code | 6113 |
Concatenated Invoice Description | Fuse TR-R - Class RK5 - Time-Delay 250VA |
Connection | Ferrule |
Description | MFZ TR7R 7A 250V RK5 TD FUSE |
Fuse Type | Time Delay |
Interrupt Rating | 200 |
Invoice Description (MFR) | Fuse TR-R - Class RK5 - Time-Delay 250VAC 160VDC 7A Ferrule |
Marketing Message (MFR) | Tri-Onic TR-R current-limiting time-delay fuses are engineered for overcurrent protection of motors, transformers, service entrance equipment, feeders and branch-circuits. The time-delay characteristics of the TR-R safely handle harmless starting currents and inrush currents associated with today's motors and transformers. |
Mounting | Clip |
Product Name | Low Voltage UL Power Fuse |
Safety Data Sheet (SDS) Flag | N |
Shipping Restrictions (MFR) | No Shipping Restrictions |
Short Description | 250V 7A 2x9/16 RK5 TD FUS |
Size | 2 x 0.56,50.8 x 14.3 |
Special Features | Time-delay Current-limiting AC & DC rated Optional solid state SmartSpot blown fuse indicator Time-delay for motor start-ups and transformer inrush currents without nuisance opening Current-limiting for low peak let-thru current Rejection-style design prevents replacement errors (when used with recommended fuse blocks) Easy-to-read label for quick brand recognition and replacement Metal-embossed date and catalog number for traceability and lasting identification Fiberglass body provides dimensional stability in harsh industrial settings High-grade silica filler ensures fast arc quenching and high current limitation |
Standard | UL listed to standard 248-12 File E2137 CSA certified to standard C22.2 no. 248.12 DC listed to UL standard 248 TRS only |
Stripped Catalog Number | TR7R |
Sub Brand | Tri-Onic® |
Type | Class RK5 |
UNSPSC | 39121604 |
Voltage Rating | 250V |
Availability
- Akron Qty 0
- Bedford Qty 0
- Chardon Qty 0
- Cleveland Qty 0
- Lighting Showroom Qty 0
- Macedonia Qty 0
- Mayfield Village (current selection) Qty 0
- Medina Qty 0
- Middleburg Qty 0
- Streetsboro Qty 0
- Westlake Qty 0
- Willoughby Qty 0
- Youngstown Qty 0